EasyManua.ls Logo

Ametek Amrel PLA Series - Page 130

Ametek Amrel PLA Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M470039-01 REV-F Page 129
System Spec with the same models in parallel
N =Number of Slave + 1,
P=Power rating of Master,
I=Current rating of Master,
R=Resistance rating of Master,
S=Slew time of Master should be less than the slew time of Slave
Psystem=P x N
Isysetm=I x N
Rsysetm=R/N
Ssystem-min=S x N if Master slew-time=Slave slew-time
Accuracy and Offset = Master Specification x N
Slew Time = Master Specification x N
1) With the same models, this configuration can be working as one single unit with increased power and current rating.
2) To further improve current accuracy in Master+Slave configuration. User can perform current calibration even in
Master+Slave mode.
3) It still has all the step, transient or pulse features. Slave slew time must be set to ½ of Master’s slew time.
4) The CC-Low, CC-Mid, CP-Low, CP-Mid, CR-Mid, CR-High\won't be used Master-Slave configuration.
5) It could have stability issue at CV mode with very low current level; this also depends upon the wiring and DUT. It
would be better adding equivalent RC filter at the input terminal for this case.