M470039-01 REV-F Page 22
FRONT PANEL OPERATION QUICK GUIDE
LCD Status Enunciator
LIQUID CRYSTAL DISPLAY:
FIGURE 1.1 LIQUID CRYSTAL DISPLAYS
Important Notes:
1) The LCD displays real time input Voltage/Current & mode status. These messages are viewed in either local or
remote mode.
2) The Front Panel and Remote read back provide 4 digits of display after the decimal point. Any numbers
exceeding the 4
th
digit will be rounded to the next significant digit and displayed as the read back value.
LCD DESCRIPTION
1) Mode Indicator: Constant Voltage (CV), Constant Current (CC), Constant Resistor (CR), and Constant Power (CP).
2) Main Setting Indicator: Main Voltage, Current, Resistance and Power Setting.
3) Local Mode/Remote Mode Indicator: Local, INSC, GPIB, RS232, ETHER, and USB.
4) Operating Range Indicator: Auto, Manual Low, Manual Middle, and Manual High.
5) Max Range Setting Indicator: Displays maximum value for the specified range.
CC 40.000A LOCAL
AUTO LOW 600A
1
2
3
4
5