M470039-01 REV-F Page 136
PEL & PLA/PLW PROGRAMMING
COMMAND COMPATIBILITY CHART
PEL COMMANDS
PLA & PLW
COMMANDS
PEL Syntax &
Parameters
PLA Syntax &
Parameters
INP[?]
INP[?]
INP[:STAT][?]
INP[:STAT][?]
SHOR
SHOR
INP:SHOR[:STAT][?]
INP:SHOR[:STAT][?]
SET[?]
SET[?]
VSET[?]
VSET[?]
VOLT[:LEV][:IMM][?]
VOLT[:LEV][:IMM][?]
VOLT[:LEV]:TRIG[?]
VOLT[:LEV]:TRIG[?]
ISET[?]
ISET[?]
CURR[:LEV][:IMM][?]
CURR[:LEV][:IMM][?]
CURR[:LEV]:TRIG[?]
CURR[:LEV]:TRIG[?]
RSET[?]
RSET[?]
RES[:LEV][:IMM][?]
RES[:LEV][:IMM][?]
RES[:LEV]:TRIG[?]
RES[:LEV]:TRIG[?]
PSET[?]
PSET[?]
POW[:LEV][:IMM][?]
POW[:LEV][:IMM][?]
POW[:LEV]:TRIG[?]
POW[:LEV]:TRIG[?]
TR[?]
TR[?]
TLEV[?]
TLEV[?]
VTR[?]
VTR[?]
VOLT:TLEV[?]
VOLT:TLEV[?]
ITR[?]
ITR[?]
CURR:TLEV[?]
CURR:TLEV[?]
RTR[?]
RTR[?]
RES:TLEV[?]
RES:TLEV[?]
PTR[?]
PTR[?]
POW:TLEV[?]
POW:TLEV[?]
SLEW[?]
SLEW[?]
Check PEL Slew Rate
Specifications
1) PLA/PLW slew
rate based on Slew
Rate Specifications
2) For PLA/PLW to
PEL slew rate
conversion, use the
following conversion
equation: [(Trans
Value - Main
Value)/[Desired Slew
Time (ms)] (A/us)]
(Note: This command
will change both +/-
Slew Rate Value)
VOLT:SLEW[?]
VOLT:SLEW[?]
CURR:SLEW[?]
CURR:SLEW[?]
RES:SLEW[?]
RES:SLEW[?]
POW:SLEW[?]
POW:SLEW[?]