Parts Description
2-15
DPS-300AB-1) shall meet the IEC-1000-3-2 Standard.
(7) Electrical performance should compatible with RPS-600A.
Static Output Characteristics:
OUTPUT
VOLTAGE
LOAD
RANGE
MIN.
LOAD RANGE
MAX.
REGULATION
RIPPLE
P-P MAX.
RIPPLE
+NOISE
+3.3V 0.5A 14A +4% ~ -4% 50mV 80mV
+5V 0.5A 33A +5% ~ -5% 50mV 100mV
+12V 0.2A 10A +5% ~ -5% 120mV 200mV
-5V 0A 0.3A +10% ~ -10% 100mV 200mV
-12V 0A 0.5A +10% ~ -9% 200mV 200mV
5V AUX 0A 0.9A +5% ~ -5% 100mV 100mV
Note : 1. +5V and 3.3V total combination output power should not over 205w.
2. The cross regulation is defined in the matrix below.
Conducted EMI :
-FCC docket 20780. Part 15. Class B.
-CISPR 22. Class B.
-BZT vfg 243 Class B requirements
-VCCI class 2 requirements.
Product safety : this power supply is designed to meet the following
specs.
-UL 1950.3
rd
. edition./CUL
-CSA C22.2 NO. 950-95
-IEC-60950 2
nd
edition.
-VDE, TUV.
-CCIB.
-CE marking.
-B.C.I.Q.
Environment :
-Operating temperature: 5 to 40 dec.C (RPS-600A & one SPS unit DPS-300AB-1)
-Operating relative humidity: 20% to 90%.
-Storage temperature: -20 to +60 deg. C
-Storage relative humidity: 5% to 95%.
-Altitude: operate properly at any altitude between 0 to 10,000 feet.
-Storage: 50,000 feet.
User’s Guide