© Ikonix USA
13
Models
8505 8512 8520 8540
System Parameters & Features
Models
Efficiency (*11)
≥74% (at Full load) ≥81% (at Full load) ≥84% (at Full load) ≥84% (at Full load)
Count 0 - 50000, 0 = Continuous
Power Up ON, OFF, LAST
Test Results
(Programmable Option) List mode only
Over Current Fold Back
Test results are recorded for List Mode only as long as the following conditions for test frequency
and time are met:
5.0 Hz - 10.0Hz Time≥200.1msec
10.1Hz - 100.0Hz Time≥ 100.1msec
100.1Hz - 1200.0Hz Time≥ 10.1msec
Lock ON, OFF
Fan Speed Temperature-controlled fan speed
Rack Mount Kit Standard
Rear Output Terminal Block (L,N, G, Ls, Ns)
Rear Input AC Outlet Terminal Block
Memory
LIST Mode - 100 x 100 (file x sequence)
MANUAL, STEP and PULSE - 100 files
Sync Signal / Ext Trigger
(Programmable Option)
ON / START / END / BOTH / OFF / EVENT, Output Signal 5V, BNC type
Safety CE
Dimension by Model (mm)
W 430 430 430 430
H 88 88 88 176
D 500 500 500 500
Weight 15KG 15KG 15 KG 28KG
Storage Environment -40° to 75°C
Operation Environment (*13) 0-40°C/20-85% RH