Detailed descriptions of all the available test parameters in the Pulse Mode are listed in the following
table:
Step Mode - Test Parameters
Parameter Setting/Range Description
Count 0 – 50000 0=Off Sets the number of counts.
Trigger Auto/Manual Sets the trigger to auto or manual for triggering the counts.
Range
Auto
Sets the power source in an Auto Range mode. The power source will
automatically interpret the voltage range and switch to high or low
voltage output range.
High
Sets the power source in the High Range mode for voltage output.
The current will be limited to half of its full range. See section 3.1
Specifications.
Low
Sets the power source in the Low Range mode for voltage output. Full
current will be available in the mode. See section 3.1 Specifications.
Wave
SINE, TRIANGLE,
SQUARE, CSIN
Sets the output waveform to the desired type.
Vac 0.0 – 310.0V Starting AC voltage for the sequence.
F 5 – 1200Hz Starting frequency for the sequence.
Vdc 0.0 – 420.0V Starting DC voltage for the sequence.
Start Angle 0 - 359°
Provides flexibility to select the starting angle of the sine wave when the
output voltage is generated.
Trans Vac 0.0 – 310.0V Sets the transient AC voltage.
Trans Vdc 0.0 – 420.0V Sets the transient DC voltage.
Duty 0 -100% Sets the duty cycle of the transient voltage for the period.
Period 0 – 999.9ms Sets the total time period for each count.