AQUA SALT
+
MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine genera ENGLISH
ADSP7000753 rev. 5.0 09/07/2019 10/51
✓ OTHER MODES:
There are other operating modes related to system's restart, first installation or maintenance:
• Superchlorination (boost): When this work mode is on, the generator stops its internal
adjustments and starts working at 100% for 12 hours. At the end of superchlorination, the generator
goes back to the set work mode. We suggest to wait up to 15 minutes between two consecutive
boosts.
✓ OTHER FEATURES:
• Salinity control: This system estimates the salt level of water every time chlorine generation is
enabled. The value depends on current intensity, and it is reliable only if the electrodes are clean.
Depending on the calculated value, the system can run several operation
• Automatic brine dosing
It is possible to increase salt concentration with the help of an external pump that automatically
doses brine depending on the estimated salinity result.
• Estimated chlorine generation
The system provides an estimate of the generated chlorine that includes the ratio between salinity
concentration, current efficiency and temperature.
pH electromagnetic pump output
Brine dosing electromagnetic pump output
Electrolytic cell self clearing
Replaceable electrolytic cell
Automatic chlorine regulation
Superchlorination mode (boost)
Estimated useful life of the electrolytic cell
Flow sensor/Pressor switch
pH reading and pH pump injection
Chlorine reading through AJ cell
Chlorine reading through Redox probe
✓ Available Not available Optional
2.4
Chlorine
generator
models
Depending on the additional operating modes and accessories it is equipped with, there are 4 main models
of chlorine generators:
• STANDARD.
• pH: includes a pH probe to monitor the pH of the water and a peristaltic pump to dose the pH
corrector.
• pH/CLJ: includes two probes to monitor the pH and chlorine values; a peristaltic pump to dose the
pH corrector; and a level probe.
• pH/Redox: includes two probes to monitor pH and Redox values, a peristaltic pump to dose the pH
corrector, and a level probe.