AQUA SALT
+
MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine genera ENGLISH
ADSP7000753 rev. 5.0 09/07/2019 43/51
Indicates or sets the enabling of the "Insufficient
production" alarm (On, Off).
Indicates or sets the enabling of the "Temperature probe" alarm
(On, Off).
Excessive salt alarm enabling
Indicates or sets the enabling of the "Excessive salt"
alarm (On, Off).
Temperature probe alarm enabling
Indicates or sets the enabling of the "Temperature probe" alarm
(On, Off).
Ice alarm enabling
Indicates or sets the enabling of the "Ice" alarm (On,
Off).
Temperature probe alarm enabling
Indicates or sets the enabling of the "Temperature probe" alarm
(On, Off).
Chlorine OFA alarm enabling (minutes)
Indicates or sets the enabling of the "Chlorine OFA"
alarm, and the duration of the reference period, if any
(Off, 5...60 minutes).
Salinity OFA alarm enabling (minutes)
Indicates or sets the enabling of the "Salinity OFA" alarm, and
the duration of the reference period, if any (Off, 5...60 minutes).
pH OFA alarm enabling (minutes)
Indicates or sets the enabling of the "pH OFA" alarm,
and the duration of the reference period, if any (Off,
5...60 minutes).
pH level alarm enabling
Indicates or sets the enabling of the "pH level" alarm (On, Off).
✓ Through the PASSWORD tab, you will be able to set a new password and change the current one.
Old
Insert the current password in this field if you want to replace it with a new one.
New
Insert the new password in this field if you want to replace the current one.
✓ The SATURATION INDEX tab allows to calculate an index that describes the quality of pool water
Saturation Index (SI) calculation
pH
Indicates or sets the pH value to be used to calculate the Saturation Index (SI).
This value can be automatically acquired by the pH probe, if supported.
Total Alkalinity - TAC (ppm)
Sets the total alkalinity value of the pool water to be used to calculate the
saturation index (SI)
Calcium hardness - TH (ppm)
Sets the calcium hardness value of the pool water to be used to calculate the
saturation index (SI)
Temperature
Indicates or sets the temperature value to be used to calculate the Saturation
Index (SI). The temperature probe will read this value automatically.
SI
Press "SI calculation" to calculate the saturation Index (SI) derived from the
values specified in the above-mentioned four fields. The value indicates if the
water is in good conditions, corrosive or fouling.
✓ The AUTOMATIC READINGS/GRAPHS tabs make you read and visualize the values of the data
collected, both in graphs or tables.
Automatic Readings Settings
Range
Indicates the time interval between
the readings.
Elements
The check boxes of this section
make you select the values to be
visualized in the graph, or to be
exported in a .csv file.
Graphically
visualizes the trend
of the selected
values over time.
Visualizes in a table
the trend of the
selected values over
time.
Automatic readings state
Indicates the state of the automatic
readings (Active, Not active). To
activate the automatic reading of the
values, press ‘Start’. To interrupt or
pause the reading, press ‘Stop’
Period
The fields of this section specify
the time lapse to examine the
magnitudes that have to be
visualized in the graph or
exported in a .csv file.