40 Tensor
Error messages
If the 7-segment display is present, error messages occur according to the table below. Automatic and manual operation can not be
used as long as a fault is present. The set-up can be started.
Display Function Meaning Remarks
bE
Motor Error
No valid values for motor control
from Hall sensor
Please contact your responsi-
ble ARIS contact person
SE
Sensor Error
No valid values from position sensor.
No existing magnet or out of valid range
Please contact your responsi-
ble ARIS contact person
iE
Range Error Programmed end positions too close
End positions must be
> 0.5 sensor turns (corre-
sponding 28°) apart
CE
Calibration Error
Actual output value too low
Set input value too low
Please contact your responsi-
ble ARIS contact person
sF
Sensor Fault Correlation error, not correctable
Disconnect power supply.
After re-energizing the error
should not be displayed.
PE
Parameter Error
Too low difference between
free set and actual values
At free values, the difference
must cover at least 20% of
the complete range
st
Stall Error Standstill or blockade of the motor
Please contact your responsi-
ble ARIS contact person
db
Wire break Wire break detection caused message
Examine control lines and
clamps
EE
EEprom Error
Fault in EEPROM Data, inconsistent data,
operation no longer possible
Please contact your responsi-
ble ARIS contact person