3.48 Planning DECT Systems HBT_20321104_03/B0_en
5.4.3 On-site Measuring
As soon as the concrete locations for the radio units have been planned, it is rec-
ommended to confirm the circumstances in keeping with the plan using on-site
measurements.
A detailed description on how to use the test equipment can be found in "Meas-
urements", Page 3.82.
Remarks:
Installation site for the test radio unit: To carry out the measurements do not
place the radio unit on the ground / floor but position it in the location in which
it is to be installed later.
Measurements must be meticulously carried out (no compromises). The objec-
tive is optimum radio coverage.
Documentation: It is advisable to keep a test log so results can be reproduced
later. Record the values measured as well as the supply range on the ground
plan, horizontal and vertical.
The measurements provide a reliable idea of the equipment required and the
locations for the radio units.
Co-operation with the customer: As soon as you are able to make sufficiently
binding statements about "problem areas", you should involve the customer
for clarification purposes. It is imperative that the customer be informed of any
areas where coverage is not optimum.