AC24/30/36 Operations Manual....
29
6.2 AUTO-RESTART FEATURE, cont.
6.2.1 Operation
Auto-Restart is automatically disabled when the SHORE POWER OFF button is pressed. This
ensures that a yacht’s crew is deciding prior to each extended use whether or not to employ Auto-
Restart.
Auto-Restart will no initiate when the Seamless Transfer Option is present, and a generator is on-
line open restoration of the shore power voltage.
Auto-Restart may be enabled or disabled from the converter front panel by simultaneously pressing
two buttons. Anytime the Systems Status is “FAILURE,” the converter will disable the Auto-
Restart feature. The converter must be ON and ONLINE before Auto-Restart may be enabled.
Pressing the SYSTEM STATUS (5) button will display the SUMMARY DISPLAY which will
indicate the Auto-Restart status.
CONVERTER ACTION FRONT PANEL OPERATION
Enable Auto-Restart CONVERTER POWER (4) & F1 (13)
Disable Auto-Restart CONVERTER POWER (4) & F2 (13)