4 SPECIFICATIONS
4.1 ELECTRICAL SPECIFICATIONS
Parameter
AC24 AC30 AC36
4.1.1 Input Service
Input Power Form Single Phase, Single Phase, Single Phase,
Single or dual shore cord Single or dual shore cord Single or dual shore cord
Input Voltage Range 170-520 V
AC
170-520 V
AC
170-520 V
AC
Input Frequency Range 40-70 Hertz 40-70 Hertz 40-70 Hertz
Input Current, Max. 2 x 50 A
RMS
2 x 63 A
RMS
2 x 75 A
RMS
or 1 x 100 A
RMS
1 x 125 A
RMS
1 x 150 A
RMS
Input Current, Soft Start, Max. 20 A
RMS
20 A
RMS
20 A
RMS
Input Current Distortion <8% THD @ rated load <8% THD @ rated load <8% THD @ rated load
Input Power Factor >0.98 @ rated load >0.98 @ rated load >0.98 @ rated load
4.1.2 Output Service
Output Power Rating 24kVA @ 0.85 p.f. 30kVA @ 0.85 p.f. 36kVA @ 0.85 p.f.
Output Power Form Single Phase 220, 230, Single Phase 220, 230, Single Phase 220, 230,
and 240 V
RMS
and 240 V
RMS
and 240 V
RMS
or Split Phase 110/220 Split Phase 110/220 Split Phase 110/220
and 120/240 V
RMS
and 120/240 V
RMS
and 120/240 V
RMS
Output Frequency 50 or 60 Hertz 50 or 60 Hertz 50 or 60 Hertz
Output Frequency Accuracy 0.01% 0.01% 0.01%
Output Voltage Distortion < 1% THD < 1% THD < 1% THD
Output Voltage Line Regulation 0.50% 0.50% 0.50%
Output Voltage Load Regulation 1.0% 1.0% 1.0%
Output Voltage Response Time 0.20 msec. 0.20 msec. 0.20 msec.
Output Current, Continuous 100 A
RMS
@ 0.85 p.f. 125 A
RMS
@ 0.85 p.f. 150 A
RMS
@ 0.85 p.f.
Output Current, Peak 420% of cont. rating 350% of cont. rating 300% of cont. rating
Output Current, Surge 300% of cont. rating 250% of cont. rating 200% of cont. rating
Conversion Efficiency 91% @ rated load 91% @ rated load
91% @ rated load