7.2 LOAD MANAGEMENT, cont.
Voltage Droop
If the yacht’s electrical system does not include a power management system that allows for
automatic load-shed, the converter’s Voltage Droop feature may be used to save up to 10% capacity
by reducing the converter output voltage up to 5% (1% to 5% range). This feature may be enabled
or disabled by the user and droops upon Shore Cord Alarm.
Automatic Transfer to Generator
The converter system may be set to automatically transfer to generator (assuming the existence of
the Seamless Transfer Option) upon Shore Cord Alarm. The Automatic Transfer would only occur
after the Voltage Droop had taken effect if both were enabled. This feature may be enabled or
disabled by the user. A signal generated by the converter may be used to start the selected generator.
Also, a programmable warm-up delay is available.