Commands and Parameter LDM41A and LDM42A Manual
Page 26 ASTECH GmbH
Any command must be terminated by a hexadecimal 0Dh (carriage return)
character.
Where decimal digits are to be entered, they must be separated by period
(2Eh).
For command parameter entries, one must distinguish between parameter
settings and parameter queries.
Querying is achieved with a command in simple format, e.g. (for alarm center
parameters):
AC[Enter]
For parameter setting, a new value must be added after the command with no
delimitation sign in between, for example:
AC20.8[Enter]
In the given example, the alarm center will be set to 20.8.
The following is a short overview of the commands:
Table 5 : Commands of the LDM41A and LDM42A
Command
Description
DT
Start distance tracking
DS
Start distance tracking (< 7 m)
DW
Start distance tracking on white target at 10 Hz
DX
Start distance tracking on white target at 50 Hz (nur
LDM42A)
DF
17
Start remote triggered single distance measurement
DM
Start single distance measurement
TP
Queries inner temperature
SA
Queries/sets floating average value(1...20)
SD
Queries/set output format (dez/hex/sig)
ST
Queries/set time to measure(0...25)
17
Trigger function is not available for devices with internal heating (LDM41A-h and LDM42A-h)