63
Operation
Parameter listing
24. 6. 4 Multi In AD 1
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Timer CH
8 = Gas Pressure Switch
0 - 8 0
24. 6. 5
Multi In AD 2
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Flue gas damper feedback
8 = Pressure Switch
0 - 8 0
24. 6. 6 Multi In AD 3
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Flue gas damper feedback
8 = Pressure Switch
0 - 8 0
24. 6. 7
Multi In AD 4
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Flue gas damper feedback
8 = Pressure Switch
0 - 8 0
24. 7 &RQ¿JXUDEOH,QSXWV2XWSXWV
24. 7. 0
Multi Out HV
0 = None
1 = System pump
2 = HC1 Pump
3 = Circulating pump
4 = DHW intermediate circuit pump
 %8)¿OOLQJSXPS
6 = Storage tank transfer pump
 +HDWJHQVKXWRႇYDOYH
8 = Heat request
0 - 8 1