64
Operation
Parameter listing
Menu
Submenu
Parameter
Name Description Range
Factory
settings
24. 7. 1 Free Contact 1
0 = None
1 = System pump
2 = HC1 Pump
3 = Circulating pump
4 = DHW intermediate circuit pump
 %8)¿OOLQJSXPS
6 = Storage tank transfer pump
 +HDWJHQVKXWRႇYDOYH
8 = Heat request
9 = Alarm output
10 = Flue Gas Dumper
11 = Lpg/Room Supply Fan
0 - 11 0
24. 7. 2
Free Contact 2
0 = None
 +HDWJHQVKXWRႇYDOYH
2 = Heat request
3 = Alarm output
4 = Lpg/Room Supply Fan
0 - 4 0
24. 7. 3 Free Contact 3
0 = None
 +HDWJHQVKXWRႇYDOYH
2 = Heat request
3 = Alarm output
4 = Lpg/Room Supply Fan
0 - 4 0
24. 7. 4
Multi Out PWM 1
0 = None
1 = System pump modulator
2 = DHW Pump modulator
3 = Circulating pump modulator
 %8)¿OOLQJSXPSPRGXODWRU
5 = boiler power feedback
0 - 5 1
24. 7. 5
Multi Out PWM 2
0 = None
1 = System pump modulator
2 = DHW Pump modulator
3 = Circulating pump modulator
 %8)¿OOLQJSXPSPRGXODWRU
5 = boiler power feedback
0 - 5 0
24. 8 Boiler manual settings
24. 8. 0
Manual mode activation
OFF
ON
0 - 1 0
24. 8. 1
Boiler pump control
OFF
ON
0 - 1 0
24. 8. 2
Fan control
0 = OFF
1 = ON
0 - 1 0