3.10 Status data menu
Warning
Before starting any maintenance or repairs, press the stop button (4) and wait until the
compressor has stopped. Close the air outlet valve and press the test button on top of
the electronic water drain(s) until the air system between the air receiver and outlet
valve is fully depressurised. Press the red emergency stop button and open the isolating
switch (customer's installation) to switch off the voltage to the compressor.
Before remedying, consult sections Safety precautions and Problem solving.
Function
Control panel
The Status data submenu gives information regarding the status of the compressor protection functions
(shut-down, shut-down warning, service warning and warning) and allows resetting of a shut-down, motor
overload and service condition.
Procedure
Starting from the Main screen (see Main screen menu):
• Press the key ‘Menu’ (F1): the option ‘Status data’ will be followed by a horizontal arrow.
• Press the tabulator key (2).
No message exists
• General alarm LED (1) is out and the message on the display will indicate that all conditions are
normal:
‘All Conditions are OK’
.
.
‘Menu’
F1 F2 F3
A shut-down message exists
• If the compressor is shut down, LED (1) will flash.
• In the event of a shut-down due to too high a temperature at the outlet of the compressor element:
Instruction book