3.11 Measured data menu
Control panel
Function
To call up information regarding the actually measured data and the status of some inputs such as the motor
overload protection. Consult the menu flow in section Control programs.
Procedure
Starting from the Main screen (see Main screen menu):
Press the key ‘Menu’ (F1).
Press the arrow down key (1) until ‘Measured data’ is followed by a horizontal arrow.
Activate the menu by pressing the tabulator key (2).
By pressing the scroll keys (1), a number of actually measured data can be found.
If one of the sensors is linked to a shut-down, service or warning function, both the actually measured
value as well as the corresponding shut-down, warning or service level can be called up by pressing
key (2).
3.12 Counters menu
Control panel
Function
To call up:
The running hours
The loaded hours
The number of motor starts
The number of hours the regulator (module) has been under tension
Instruction book
36 API603130

Table of Contents