Element outlet
˚C
‘Shdw’ ‘Max.’ 116
‘Menu**’ 110
F1 F2 F3
• The screen indicates that the temperature at the outlet of the compressor element exceeds the
programmed shut-down warning level.
• If necessary, stop the compressor by means of stop button (4) and wait until it has stopped.
• Switch off the voltage, inspect and remedy.
• The warning message will disappear automatically as soon as the warning condition disappears.
A service warning exists
• LED (1) is lit. The Main screen will change into a screen similar to the one below:
‘Compr. Outlet’
bar
‘*Serv.Requir.*’
‘Menu**’ ‘**Unld’
F1 F2 F3
• The indicators (**) are flashing and the service warning message appears alternately with the
messages indicating whether the compressor runs unloaded or loaded.
• Press the key ‘Menu’ (F1) and the tabulator key (2) to select the ‘Status data’ menu: the option
‘Service’ is flashing.
• Scroll to this option and select it by pressing the tabulator key (2); following option(s) may flash:
• ‘Inputs’: if the programmed service level of a component is exceeded (e.g. the maximum
pressure drop over the oil separator element).
• ‘Plans’: if a service plan interval is exceeded.
• Stop the compressor and switch off the voltage.
• If the service message was referring to ‘Inputs’ (oil separator): replace the separator element, switch
on the voltage, scroll in the ‘Status data’ menu to ‘Inputs’ and press the ‘Reset’ key to reset the
service message.
• If the service message was referring to ‘Plans’: carry out the service actions related to the indicated
plans. Reset the timers of the related plans. Contact your Atlas Copco Customer Centre. See section
Service menu.
A warning message exists
• LED (1) is lit and a warning message will appear on the screen.
• The indicators (**) are flashing and the warning message appears alternately with the messages
indicating whether the compressor runs unloaded or loaded. This warning indicates that:
• On Full-Feature compressors with integrated dryer the dewpoint temperature is too high in
relation to the ambient temperature.
• Stop the compressor and switch off the voltage. Inspect the compressor and remedy.
Instruction book
API603130 35