EasyManua.ls Logo

Atlas Copco GA 55+

Atlas Copco GA 55+
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
‘Service Timer’
‘Running Hours’
‘hrs’ 2130
‘Menu’
F1 F2 F3
The screen shows the actual running hours.
Press the tabulator key (2): a screen similar to the one below will appear:
‘Service Timer’
‘Level A’
‘hrs’ 4000
‘Menu’ ‘Mod.’
F1 F2 F3
The screen indicates that the level for Service plan A is set at 4000 running hours.
Press the ‘Mod.’ key (F2). The key ‘Lim.’ (F2) can be used to find out the limitations for the
parameter. Use the arrow up and arrow down keys to modify the interval.
Press the ‘Prog’ key (F1) to program the new setting or the ‘Canc’ key (F3) to cancel the modification
operation.
The procedure to modify the Service plans B, C and D is similar.
3.18 Programming clock function
Control panel
Function
To program:
Time-based start/stop commands for the compressor
Time-based change-over commands for the net pressure band
Programming start, stop and pressure band commands
In this example, the compressor will be programmed as follows:
On Monday at 06:15 starting in pressure band 1
On Friday at 18:00 changing over to pressure band 2
On Saturday at 18:00 stopping
Instruction book
42 API603130

Table of Contents

Related product manuals