Control panel of Elektronikon II
Step Action
- Open the air outlet valve.
- Switch on the voltage. Check that voltage on LED (6) lights up.
5.4 During operation
Warnings
The operator must apply all relevant Safety precautions. Also consult section Problem
solving.
Keep the doors closed during operation; they may be opened for short periods only to carry
out checks.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may
start automatically.
Checking the oil level
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Instruction book