Control panel, Elektronikon II
Regularly check the oil level during loaded operation. The pointer of level gauge (Gl) must register in the
green range.
If the oil level is too low, press stop button (9). Wait until the compressor has stopped and depressurised
and push the emergency stop button (10) to avoid the compressor to start unexpectedly. Next, close the air
outlet valve and press the test button on top of the electronic water drain(s) (two water drains are provided
on Full-Feature compressors) until the air system between oil separator/air receiver vessel and outlet valve
is fully depressurised. See section Condensate system for location of the outlet valve and water drain.
Instruction book
API603130 67