to trickle charging (13.3 V) when the battery is fully
charged.
Battery storage and trickle charging
Never leave a machine with a discharged battery. A
discharged battery freezes at a temperature of about
-7°C (19F). A fully charged battery will freeze at
-67°C (-89F). A battery that is not being used must
be fully charged before being put aside.
Trickle charging is not normally required during a
period of 6 to 8 months. If a battery has not been in
use for a long period, it must be fully charged before
being used. Trickle charging is recommended a
couple of times during the season (especially in
winter).
Desktop charger
WARNING Explosion
If the battery is charged in a damp room at a high
temperature, it might explode.
Use charger only in a dry room within the
temperature range -25-70°C (-13-158°F).
The desktop charger works within a voltage range
of100-240 V.
The desktop charger comes with an adapter that
works in most sockets.
A steady yellow light indicates that the charger is
ready for charging. Place the battery in the charger.
The charger verifies the battery, which takes 10
seconds. If battery is accepted the charge starts. Full
charge time is 2.5 hours at a normal temperature.
The battery will not be damaged if it is left in the
charger when fully charged.
When the battery is removed from the charger, wait
until the LED indicator turns yellow before inserting
a new battery for charging.
Battery statusLED indicator
Battery verificationYellow
Fast chargeOrange
Top-off chargeGreen with intermittent yellow
flash
Trickle chargeGreen
ErrorAlternating orange-green
Fuses
F
E
D
C
B
A
A. Main fuse, 30 A
B. Radio receiver + Electronic Control Unit, 5 A
C. Battery charger, 20 A
D. Strobe, 10 A
E. Tilt sensors, 10 A
F. 12 V power socket, 10 A
Every 10 hours of operating
(daily)
Before undertaking any maintenance, turn the
machine off.
Inspect the machine before starting. Inspect the
entire machine so that leakages or other faults are
detected.
Check the ground under the machine. Leakages
are more easily detected on the ground than on
the machine itself.
In order to ensure that the machine remains within
the stated vibration level values, the following checks
must be performed:
© 2015 Construction Tools EOOD | No. 9800 1147 01d | 2015-11-11
Original instructions
24
LP 8504Safety and operating instructions