Note 6: Connector with 4 feet 16-3 cord attached.
Delivered with KIM HOTSTART glowplugs nrs: 0W650100-000 or 0W650200-000
No KIM HOTSTART part number is available.
contact MF1 department for delivery arrangements
Middle wire (ground) is separately insulated.
Residual insulation from wire separation on wire ends shall be removed before splicing.
Power supply plug shall be removed.
Note 7: Wire insulation should be resistant to oil, fuel & coolant.
Note 8: All terminals may be replaced by an equivalent part with the same functionality.
Contact engineering department before making any changes.
Note 9: Wires to be held together by a 200mm nylon spiral.
Note 10: Marking to be printed on each end of all wires.
Note 11: Wire harness shall be provided with a marking label with AC part number
and edition.
Note 12: Label indicating AC part. Nr. and edition, testing and/or production date, supplier reference.
Black text on white background.
Note 13: Wire harness finishing; Black braiding, unless stated otherwise.