6.4.8 Servicing water separator
The water separator in the back of the unit filters
water condensate out of the compressed air, before
the air is discharged through the outlet valves.
Adjust the needle valve opening according to the
condensate flow. Do not open or close the valve
completely during operation. Open the needle valve
during service completely for drain of any debris
collected in the needle valve orifice.
Water condensate from the water separator is drained
through a drain hole in the bottom of the frame. Use
an appropriate drain pan and make sure that the
condensate is properly disposed of.
6.4.9 Servicing automatic fire
suppression system
Preventive maintenance
To prevent the nozzles from getting dirty, ensure that
the nozzles are covered by caps.
Check the heat sensitive detection wire for actual
damage. A damaged detection wire can lead to a false
release of the fire suppression system.
Periodic maintenance
To give maximum assurance that the system will
operate as intended, maintenance must be performed
every six months or sooner, depending on the
operating and/or environment conditions.
Maintenance must be performed by authorized
personnel only. Please contact Atlas Copco.
All maintenance activities are to be recorded in a
logbook.
Do not use a high pressure cleaner
to clean the fire suppressing system
or parts of it.
!