Reassemble in reverse order of dismantling.
Inspect and tighten all air intake connections.
6.4.2.4 Cleaning the filter element
Withdraw the filter element (see section 6.4.2.3).
Reinstall the dust trap cover to protect the air
intake system while cleaning the element.
Carefully knock the end faces of the filter element
on a flat surface to remove the dry contaminant.
Never strike on a hard surface. Then blow dry air
up and down the pleats in the reverse direction of
normal flow; subsequently blow up and down the
pleats on both sides of the element. The air
pressure may not exceed 5 bar (73 psi) and a
reasonable distance must be maintained between
the hose nozzle and the pleats.
Inspect the element by placing a light inside it.
Spots or ruptures of the paper render the element
unfit for further use.
Reassemble in reverse order of dismantling.
6.4.3 Fuel system
6.4.3.1 Draining fuel filters
The fuel system comprises:
Drain condensate from the primary coarse fuel filter
(water separator) regularly by loosening the drain
plug (3). Catch the condensate in a drain pan. Tighten
the plug after draining.
Never run the compressor without
air filter element.
!
1
One primary coarse fuel filter / water
separator
2 One secondary engine fuel filter
2