- 80 -
Intercooler pressure below normal Choked air filter elements. Remove and inspect air filter elements.
Clean or replace elements, if necessary.
Intercooler relief valve leaking. Remove valve, clean and inspect.
Air leak between LP and HP compressor element. Inspect pipe connections and intercooler.
Replace leaking O-rings, gaskets or intercooler, if necessary.
LP compressor element not in order. Have LP compressor element inspected by Atlas Copco.
Intercooler clogged internally. Consult Atlas Copco.
Intercooler pressure above normal Aftercooler clogged internally. Consult Atlas Copco.
HP compressor element not in order. Have HP compressor element inspected by Atlas Copco.
HP silencer and/or check valve give restriction. Check and take corrective action.
Symptom Possible cause Corrective action