EasyManua.ls Logo

Atlas Copco QAS 60 Pd S3A ESF - Page 63

Atlas Copco QAS 60 Pd S3A ESF
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 63 -
Crankcase pressure
Restriction in breather pipe.
Vacuum pipe leaks or fault in exhaust.
Bad compression
Restriction in air filter/cleaner or induction
system.
Incorrect valve tip clearances.
The engine starts and stops
Dirty fuel filter element.
Restriction in air filter/cleaner or induction
system.
Air in fuel system.
The engine shuts down after approx. 15 sec.
Bad connection towards oil pressure switch/
coolant temperature switch

Table of Contents

Related product manuals