- 63 -
Crankcase pressure
Restriction in breather pipe.
Vacuum pipe leaks or fault in exhaust.
Bad compression
Restriction in air filter/cleaner or induction
system.
Incorrect valve tip clearances.
The engine starts and stops
Dirty fuel filter element.
Restriction in air filter/cleaner or induction
system.
Air in fuel system.
The engine shuts down after approx. 15 sec.
Bad connection towards oil pressure switch/
coolant temperature switch