e-tron
LED on the vehicle @ Meaning Solution
Have the power supply or power
supply system inspected. Check
No power supply was recognized the status display on the control
On even though the charging cable is unit
c> table on page 112 . See an
Yellow
plugged in. authorized Aud i dealer or author-
ized Audi Service Facility for ass is-
tance if necessary.
Flashes
The se lector lever in not in the P Move the selector lever into the P
position. posit ion.
Check if the charging connector is
inserted correct ly
c> page 110. Re-
The charging connector cou ld not move the charging connector and
On
be correctly locked in the vehicle insert it into the charging port
charging port . again. See an authorized Audi
dealer or author ized Audi Service
Red
Facility for assistance if necessary .
Fault in the charging system. The
high -voltage battery cannot be
See an author ized Audi dealer or
charged.
Flashes autho rized Audi Service Fac ility for
Or: the outside temperature is too
assistance if necessary.
low. The high-voltage battery
could not be fully cha r ged .
(D Tips
- Current capacity of the charging connector.
The operation statuses indicated by the LED
@ on the vehicle are also displayed in the in-
strument cluster display/Infotainment sys-
tem.
Charging time
Applies to: vehicles with pl ug-in hybrid drive
The length of the charging process usi ng the Audi
e- t ron charging system can vary based on t he fol-
lowing factors:
- Sockets be ing used (household or industr ial
sockets).
- System voltage and current strength specific to
a country.
- The value set for the charg ing power leve l on
the control unit (50% or 100%).
- Fluctuations in the system voltage .
- Temperature outside the vehicle.
- Temperature of the high-voltage battery .
- Adjustments to the climate control inside the
vehicle.
114
- Ignition is on/off .
Example charging times
Connection Charging time at
100% charge
Household socket approximately 10
(100 V, 10 A) hours
Househo ld socket approximately 8.2
(110 V, 10 A)
hours
Household socket approx imately 5.2
(220 V, 8 A)
hours
Household socket
approximately 3 .8
(230 V, 10 A) hours
Industria l socket (200 V, approximately 2.3
16 A)
hours
Industrial socket (220 V, approximately 2.3
16 A) hours
Industria l socket (230 V, approximately 2.3
16 A)
hours
Industria l socket (240 V, approximately 2.3
16 A)
hours