Installing the AVPP
Issue 6, January 2011 17
Connect Power
1. Once the units have been properly grounded, connect the power plug from the AC
adapter to the jack labeled PWR on the AVPP Server.
Use only the Avaya-provided Class II AC Adapter with output 24VDC, 1A.
2. Plug the AC adapter into a wall outlet to apply power to the Avaya Voice Priority
Processor.
3. Verify that leakage current ("touch" current) is below 250 μA rms on exposed metal
surfaces.
4. If leakage is excessive, power off the system and re-verify ground path continuity.
5. The system will cycle through diagnostic testing and the LEDs will blink for about one
minute. When the system is ready for use:
The ERROR LED should be off.
Status 1 should be blinking.