03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
29
Table below: Brake forces for ribbon unwind and ribbon rewind mandrel.
Printer Tractive force rewind
mandrel
Tractive force unwind
mandrel
Label width
Min. Setting Max. Min. Setting Max.
64-04 1
+1
N 5 N 9
+2
N 1
+1
N 7 N 10
+2
N 105 mm
64-05 1
+1
N 6 N 9
+2
N 1
+1
N 7 N 10
+2
N 140 mm
64-06 1
+1
N 10 N 13
+2
N 1
+1
N 13 N 17
+2
N 155 mm
64-08 1
+1
N 15 N 16
+2
N 1
+1
N 16 N 17
+2
N 250 mm
Setting the functional brake force
With the settings given above, the range that
can actually be set corresponds to the
permissible range for the braking torque.
Screw the threaded rod in until it stops
then screw it out again by about
2 rotations.