03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
58
Cover switch
CAUTION! - Ensure the functional
capability of the hood switch at all
times!
The cover switch (1) is a protective device and
is for safeguarding operating personnel. The
valid safety regulations stipulate that the
device may only function when the hood is
closed.
Disassembling/assembly
1. Remove the rear hood.
2. Detach the hood switch cable from the
mainboard.
(2a) CPU boards no. A2292, A2293 (…6/06)
(2b) CPU board no. A6621 (7/06…)
3. Remove the hood switch on the base
plate of the device with the two
screws (3).
4. If necessary replace the hood switch.
Setting:
1. Check the functioning of the device
using the parameter
SERVICE FUNCTIONS > Sensor test:
Hood Display text
open
Sens.: 9.01 15
closed
Sens.: 9.01 0
2. If necessary, adjust the switch flag on
the hood (if fitted).
Tool
Screwdriver
3