EasyManua.ls Logo

Avery Dennison 6405 - Ribbon Core Brake; Ribbon Guide

Avery Dennison 6405
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
30
Ribbon core brake
The clamping of the paper core on the ribbon
unwinding core and the ribbon roll-up core can
be adjusted by setting the spring plate.
Setting:
1. Unscrewing the Phillips screws (1).
2. Setting of the securing plate (2) to the
required core diameter.
3. Fixing with the Phillips screws.
If one of the threads is stripped, move the
spring plate along the axis and reaffix it.
Tool
Phillips size 1
Ribbon guide
The ribbon guide mandrel is for the non-
contact feeding of the ribbon to the thermal
bar.
Disassembling/assembly
1. Unscrewing the fastening screw in the
cast block.
2. Remove the guide mandrel (1) to the
front.
Tool
Socket wrench SW 10
1 2
1

Table of Contents