03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
45
Adjustment
1. Turn the sliding block (1) to the lowest
position (print position).
2. Lay 0.1 mm thick material (2) between the
sliding block and the contact arm (3) (e. g.
folded backing paper).
3. Press the contact arm against the sliding
block and retighten the screw.
4. Remove the 0.1 mm stripe.
5. Press the Feed button.
Head adjust
Sens.: 3.01 255
6. Turn the oscillator disc (4) until the
notch (5) reaches the highest point
(12 o´clock).
7. Slowly turn the oscillator disc with the notch
in direction towards the sensor, until
0 (zero) appears on the display.
Head adjust
Sens.: 3.01 0
8. Carefully retighten the fastening screw of
the oscillator disc.
Tightening torque: 20 Ncm. Do not
overtighten, because otherwise the plastic
thread will be damaged. Do not
undertighten, because otherwise the disc
will not clamp sufficiently on the motor axle.
9. Press the Online button. Press the Esc
button twice.
3
2
1
5
LS
4