22
Avid NEXIS | E5 Fan
Avid NEXIS | E5 Fan LED Status
c
Leave failed power supply or cooling modules in place until you have a replacement so you maintain the
proper airflow. Obtain a replacement as soon as possible.
Off On Off Mains AC to this PSU is missing (This PSU is on standby, other
PSU is OK)
On On On GEM software has lost communication with PSU
On --- Off PSU has failed
2200W PSU LED Status
PSU Fail
(Amber)
AC Fail
(Amber)
Power OK
(Green) Status
Fan OK
(Green)
Battery fault
(Amber)
Fan fault
(Amber) Status
--- --- Off Fan OK
--- --- On Communication lost with fan module controller
--- --- On Reported fan speed is out of tolerance
On Off --- Fan and battery OK
Flashing Off --- Battery charging
Off On --- Battery fault
On --- Off PSU has failed