11.10.1 Users and Levels
Figure 37.15: User and Level Settings
The User and Level menu gives the user the option create or alter user accounts for the Oxygen 4
Digital. In the 'change settings' menu you can adjust the name and the security level of the user. You
can also assign a password to the user.
Note: The password is case sensitive.
Each user has the ability to store his personal settings made on the control-surface and in the Global
Settings menu. The 'Store' button stores your personal settings inside the Oxygen 4 Digital. 'Recall'
loads your personal setting for you.
Each user has an extra checkbox called 'Preset by Chip-card'. When this option is set you preset will
automatically be loaded as soon as you insert your chip-card in the control-surface.
Note: When removing a chip-card, the user will change but the loaded settings will stay!
The following setting are stored in a user-preset;
Module 1..8: - Source
- Gain
- Mono
- EQ High
- EQ Mid
- EQ Low
- EQ On
- Dynamics
- Aux Level
- Panning
- Prog ON
- Sub ON
Global Settings - EQ Range
- Aux PRE/POST