System Options
If the card’s status shows as failed, click Check disk to see if the problem can be found and then try Repair.
To avoid lling the card, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings
older than and select the number of days or weeks.
To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.
For more information, see the online help
.
Network Share
Network share allows you to add network storage such as a NAS (Network Attached Storage) or any server that uses CIFS (Common
Internet File System) and use them for storage of recordings.
To add a netwo rk share:
1. Go to System Options > Storage.
2. Click Network Share.
3. Enter the IP address, DNS or Bonjour name to the host server in the Host eld.
4. Enter the name of the share in the Share eld.
5. If required, select The share requires login and enter the u se r name and passwo rd.
6. Click Connect.
To clear all recor dings and data from the Axis product’s folder on the d es ignated share, click Clear under Storage Tools.
To avoid lling the share, it is recommended to remove recordings continuously. U nder Recording Settings,selectRemove recordings
older than and select the number of days or weeks.
To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.
Ports & Devices
I/O Ports
The Axis product provides one input port and one output port for connection of exte rna l devices. For information on how to
connect external devices, see Connectors, on page 5 .
The I/O ports are congured under System Options > Ports & Devices > I/O Ports. The ports can be given descriptive names and their
Normal states can be congured as Open circuit or Grounded circuit.
Port Status
The list on the System Options > Ports & Devices > Port Status page shows the status of the product’s input and output ports.
Maintenance
The Axis product provides several maintenance functions. These are available under System Options > Maintenance.
Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
Click Restore to reset most settings to the factory default values. The following settings are not affected:
the boot protocol (DHCP or static)
the static IP address
44

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis P3344 and is the answer not in the manual?

Axis P3344 Specifications

General IconGeneral
Maximum resolution1280 x 800 pixels
Pan range0 - 360 °
Tilt angle range0 - 170 °
Angle of rotation340 °
Camera shutter speed1/25000 - 1/6 s
Minimum illumination0.4 lx
Sensor typeCMOS
Optical sensor size1/4 \
Focal length range3.3 - 12 mm
Video motion detectionYes
Power source typePoE
I/O portsRJ-45
Dimensions (WxDxH)96 x 96 x 148 mm
Processor modelARTPEC-3
Flash memory128 MB
Supported network protocolsIPv4/v6, HTTP, HTTPS, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS.
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Weight445 g

Related product manuals