EasyManuals Logo

Axis Q1755 User Manual

Axis Q1755
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
24
AXIS Q1755/-E - Live View Config
User Defined Links
User defined links can link to web pages, or can be used to run
scripts or activate and control external devices connected to the
network camera. Once configured, the links appear on the Live
View page.
To set up a link, check the Show custom link box, select the cgi
or web link radio button, enter the URL and a descriptive name
in the provided field.
A link defined as a web link will open in a new window, while a
cgi link will run for example a script in the background.
User defined cgi links can be used to issue API requests. For more
information on the VAPIX Application Programming Interface
(API), see the Video developer pages at Axis Web site
www.axis.com/developer
Output Buttons
The output buttons are used to manually activate and inactivate the output port, for example, to switch a light on and off. To
display the output buttons on the Live View page, select the type of control to use for the port from the drop-down list:
Pulse - Activates the output for a defined period of time
Active/Inactive - Displays two buttons, one for each action (on/off)
See also Ports & Devices, on page 45.
Input/output ports are specified at System Options > Ports & Devices > I/O Ports
User defined link

Other manuals for Axis Q1755

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis Q1755 and is the answer not in the manual?

Axis Q1755 Specifications

General IconGeneral
Maximum resolution1920 x 1080 pixels
Camera shutter speed1/10000 - 1/2 s
Minimum illumination2 lx
Sensor typeCMOS
Optical sensor size1/3 \
Sample rate16 kHz
Supported network protocolsIPv4/v6, HTTP, HTTPS, QoS Layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS, Pelco-D
Power source typePoE
Power over Ethernet (PoE)Yes
Power consumption (typical)17.4 W
Ethernet LAN (RJ-45) ports1
Dimensions (WxDxH)186 x 85 x 211.4 mm
Power requirements20 - 24 V AC
CertificationEN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-1, EN 61000-6-2, EN 60950-1, FCC Part 15, Subpart B, Class B, VCCI, Class B ITE, C-tick AS/NZS CISPR 22, ICES-003, Class B
Processor modelARTPEC-3
Flash memory256 MB
Internal memory128 MB
Operating temperature (T-T)0 - 45 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Weight985 g