5.5.4 Easy-Clean clamping mechanism
We are delighted to inform you that your handpiece contains our newly developed, innovative
and patented Easy-Clean clamping mechanism (hereinafter referred to as "Easy-Clean").
In a conventional clamping mechanism, the dirt that arises when working can cause an
instrument you are operating with your handpiece to stop, even though the motor is running.
This can be accelerated even further by creams, oils, fats or the like. The consequence: The
clamping mechanism is no longer functional or only functional to a limited extent and
previously needed to be sent to the factory for maintenance and cleaning. To save you from
doing this in future, we have developed Easy-Clean. You can easily clean Easy-Clean yourself
without great expense or effort.
The Easy-Clean grips need to be cleaned at least once a month!
Recommendation: In the case of an average of 8 to 10 treatments per day, you should clean
the grips every 14 days with the tool supplied. If you additionally want to clean the grips every
day for hygiene reasons as well as the device itself please only use the clamping
mechanism cleaner 2 (brush) with alcohol.
It is essential that you read this section with the utmost care! It contains
important information on protecting yourself, others and the device from
damage! It must only be used by trained professionals.
Never perform cleaning work or change a filter on a device that is still connected
to the mains. Turn off the device at the main switch beforehand and disconnect
it from the power supply.
Caution risk of injury! Never try to perform cleaning work on the
handpiece while the handpiece motor is running. The handpiece motor
must be switched off.
Only the appropriate tool should be used to clean Easy-Clean. Other types and
fields of application are carried out at your own risk, and may conceal dangers.
No form of misappropriation is permitted.
Improper use may lead to damage to persons or objects.
The manufacturer cannot be held responsible for damages caused by improper
use, unqualified staff or incorrect operating.
All warranty claims are void following improper use.
The clamping mechanism cleaner must only be used only for Easy-Clean
(developed for self cleaning). With conventional clamping mechanisms which
are not intended for self cleaning, under no circumstances must the clamping
mechanism cleaner be used, as the clamping mechanism will immediately
suffer damage.
Clean the clamping device cleaner 1 after each use and make sure that it is
always in a perfect hygienic condition before use.
We recommend a brush (Art-No. 34916) to clean the clamping mechanism
cleaner 1.
For hygiene reasons, please clean the clamping mechanism cleaner 2 after use
under running water and then with alcohol.
The images are for illustrative purposes only. Subject to technical and optical
changes.
1x
Clamping device cleaner 1
Universal stainless steel
Art-No.: 40287
1x
Clamping device cleaner 2
(Cleaning brush for Easy-Clean)
Art-No.: 40269
To clean Easy-Clean, please proceed as follows: