MODEL 20XP AUTOFEED OPTIONS
LOR Jumper Plug
Part No.: 900-2913-51
IEC Jumper Plug
Part No.: 900-2914-09
TROUBLE SHOOTING GUIDE cont.
Autofeeds with dump blocks can be unplugged and run manually. Autofeeds with dual output
block will need a jumper plug. This can be a good test to determine if you problem is hydraulic or electronic.
NOTICE
PROBLEM POSSIBLE CAUSE SOLUTION
Feedwheels Run
In Reverse From
Normal
- Backup time set wrong. - Reset backup time. Normal setting is 180 milliseconds
(IEC) or .3 seconds (LOR)
- Sticking reverse valve. - Check solenoid operation.
- Override cartridge manually by sticking a small
allen wrench in the end of the solenoid.
- Replace solenoid and/or cartridge.
Type settings programmed
wrong.
- Reprogram or consult local dealer or Bandit Ind