Method Action Result
Remote Input
a. Double-pulse the remote line to toggle between
selections.
b. Single-pulse the remote line to save selection
and advance to "Factory Default."
3. Return the sensor to the factory default settings, if desired.
Method Action Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to save selection and advance to
"Display Orientation."
Returns to factory default factory
settings
Factory Default Settings Not Selected:
Display shows "Fd n"
Factory Default Settings Selected:
Display shows "Fd Y"
Remote Input
a. Double-pulse the remote line to toggle between
selections.
b. Single-pulse the remote line to save selection
and advance to "Display Orientation."
4. Change the display orientation, if desired.
Method
Action Result
Push Button
a. Click Dynamic (+) to toggle between selections.
b. Click Static (-) to return to RUN mode.
Inverts display to read "upside-
down"
Normal
For example: 1234
Inverted
For example:
NOTE: Icons do
not invert.
Remote Input
a. Double-pulse the remote line to toggle between
selections.
b. Single-pulse the remote line to return to RUN
mode.
Push Button Lockout
• Prevents unwanted adjustments or tampering of the push buttons
• Push buttons can be enabled or disabled only from the remote line and only during normal RUN mode
Method
Action Result
Push Button
22
Not available with push-button programming. Push buttons Disabled
• Display flashes "loc"
• Padlock icon appears
• Sensor remains in RUN mode
Push Buttons Enabled
• Display flashes "uloc"
• Padlock icon disappears
• Sensor remains in RUN mode
Remote Input
23
From RUN mode, quad-pulse the remote line to
toggle between selections.
22
0.04 seconds ≤ "Click" ≤ 0.8 seconds
23
0.04 seconds ≤ T ≤ 0.8 seconds
D10 Expert
™
– Dual Discrete Outputs