1. Congure the
rst sensor as the Master (inPt SEL = MAST).
2. In the Master sensor set-up, enter the total number of Slave sensors you will be using (tOtL SLAV = 1 - 6).
3. For each Slave sensor used, congure the input as a Slave (inPt SEL = SLVE).
4.
Give each Slave its own idenfying address (SLAV Addr = 1 - 6).
5.
Connect the Input wires of the Master and all of the Slaves together.
Note: Note: Giving two Slave sensors the same address will cause them to re their
emiers at the same me in the ring
sequence.
3.5 Adjust Mode
Sliding the RUN/PRG/ADJ mode switch to the ADJ posion allows the user to perform Expert TEACH/SET methods and Manual
Adjustment of the threshold(s).
Note: For the Dual Output models, when teaching CH2, the gain seng will be the same as the gain seng made during the CH1
teach. Reteaching CH1 may invalidate the previous CH2 teach.
3.5.1 Two-Point TEACH
• Establishes a single switching threshold
• Threshold can be adjusted by using the "+" and "-" rocker buon (Manual Adjust)
Two-Point TEACH is used when two condions can be presented
stacally to the sensor. The sensor locates a single sensing threshold
(the switch point) midway between the two taught condions, with the Output ON condion on one side, and the Output OFF condion
on the other.
Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
Darkest Taught
Condition
Lightest Taught
Condition
Position
adjusted by
Manual
Adjust
Figure 6. Two-Point TEACH (Light Operate shown)
The Output ON and OFF condions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through the program
interface for the dual output model.
Two-Point TEACH and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds aer adjustment, the GREEN display will ash 3 mes to conrm
• Slide Mode switch to RUN to complete operaon
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Two-Point TEACH:
Note: TEACH Selecon must be programmed to 2Pt tcH.
1. Enter Adjust mode.
DF-G3 Long Range Expert
™
Dual Display Fiber Amplier
16 www.bannerengineering.com - Tel: 763.544.3164