4. Exit Dynamic TEACH.
Method Acon Result
SET Buon Click the SET rocker buon TEACH Accepted
Displays alternate "PASS" with % Minimum
Dierence
10
, Sensor returns to Adjust
mode
TEACH Not Accepted
Displays alternate "FAIL" with % Minimum
Dierence
10
, Sensor returns to Adjust
mode
Remote Input Single-pulse remote input
5. Return to RUN Mode.
Method Acon Result
SET Buon Move Mode switch to RUN Display: Red - Signal Level; Green -
Threshold
Remote Input No acon required; sensor returns to RUN
mode automacally
3.5.3 Window SET
•
Sets window thresholds that extend a programmable % oset above and below the presented condion
• All other condions (lighter or darker) cause the output to change state
•
Sensing window center can be adjusted using "+" and "-" rocker buon (Manual Adjust)
•
Recommended for
applicaons where a product may not always appear in the same place, or when other signals may appear
• See Program Mode for programming the Oset Percent seng
A single sensing condion is presented, and the sensor posions window thresholds a programmable % oset above and below the
presented condion. In LO mode, Window SET designates a sensing window with the Output ON condion inside the window, and the
Output OFF condions outside the window.
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing window
center adjusted by
Manual Adjust
Output OFF Output OFFOutput ON
Figure 8. Window SET (Light Operate shown)
The Output ON and OFF condions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through the program
interface for the dual output model.
Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
◦ GREEN display shows the sensing window center value
◦ 2 seconds aer adjustment, the GREEN display will ash 3 mes to conrm
• Slide Mode switch to RUN to complete operaon
10
See Troubleshoong on page 25 for more explanaon of the % Minimum Dierence displayed aer the Dynamic TEACH method.
DF-G3 Long Range Expert
™
Dual Display Fiber Amplier
www.bannerengineering.com - Tel: 763.544.3164 19