EasyManua.ls Logo

Banner DF-G3 Long Range Expert - Page 20

Default Icon
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selecon must be programmed to wind SEt.
1. Enter Adjust Mode
Method Acon Result
SET Buon
11
Set Mode switch to ADJ Display: Red - Signal Level; Green -
Threshold
Remote Input
12
No acon required; sensor is ready for
Window SET method
2. SET Sensing Condion
Method Acon Result
SET Buon Present sensing condion
Click the SET rocker buon
Threshold Condion Accepted Displays
read "wInd SEt" then alternate "PASS"
with % Oset
13
; Sensor returns to Adjust
mode
Threshold Condion Not Accepted
Displays read "wInd SEt" then alternate
"FAIL" with minimum % Oset
13
for
sensing condion; Sensor returns to Adjust
mode
Remote Input Present sensing condion
Single-pulse the remote input
T
3. Return to RUN Mode
Method Acon Result
SET Buon Move Mode switch to Run Display: Red - Signal Level; Green - Window
Center (see Figure 9 on page 20 for
instrucons on how to display upper and
lower thresholds)
Remote Input No acon required; sensor returns to Run
mode automacally
Window SET (during RUN mode)
Upon sensor power-up, Window Center is displayed
Upper
Threshold
Displayed
Window
Center
Displayed
Lower
Threshold
Displayed
Figure 9. Upper and Lower Thresholds
11
SET Buon: 0.04 seconds "Click" 0.8 seconds
12
Remote Input: 0.04 seconds T 0.8 seconds
13
See Troubleshoong on page 25 for more explanaon of the % Oset displayed aer the Window SET method