Required Overcurrent Protecon
WARNING: Electrical connecons must be made by qualied personnel in accordance with local and naonal electrical codes and regulaons.
Overcurrent protecon is required to be provided by end product applicaon per the supplied table.
Overcurrent protecon may be provided with external fusing or via Current Liming, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For addional product support, go to hp://www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protecon (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Cercaons
Industrial
Control
Equipment
3TJJ
Class 2 power
4.1 Excess Gain Curves
1
10
100
1000
10000
0.1 1 10 100 1000
Excess Gain
Distance (mm)
24mS
8mS
1&2mS
500uS
Figure 13. Diuse—PBT16U
1
10
100
1000
10000
100000
0.1 1 10 100 1000
Excess Gain
Distance (mm)
24mS
8mS
1&2mS
500uS
Figure 14. Diuse—PBT26U
DF-G3 Long Range Expert
™
Dual Display Fiber Amplier
28 www.bannerengineering.com - Tel: 763.544.3164