Method Acon Result
SET Buon • Present sensing condion
• Click the SET rocker buon
Threshold Condion Accepted Displays
read "Lt SEt" then alternate "PASS" with %
Oset
16
; Sensor returns to Adjust mode
Threshold Condion Not Accepted
Displays read "Lt SEt" then alternate "FAIL"
with minimum % Oset
16
for sensing
condion; Sensor returns to Adjust mode
Remote Input • Present sensing condion
• Single-pulse the remote input
3. Return to RUN Mode
Method Acon Result
SET Buon Move Mode switch to RUN Display: Red - Signal Level; Green -
Threshold
Remote Input No acon required; sensor returns to RUN
mode automacally
3.5.5 Dark SET
•
Sets a threshold a programmable % oset above the presented condion
• Any
condion lighter than the threshold condion causes the output to change state
• Threshold can be adjusted using "+" and "-" rocker buon (Manual Adjust)
•
Recommended for applicaons where only one
condion is known, for example a stable dark background with varying lighter
targets
• See Program Mode for programming the Oset Percent seng
Note: Oset Percent MUST be programmed to Minimum Oset to accept condions of no signal (0 counts).
A single sensing condion is presented, and the sensor posions a threshold a programmable % oset above the presented
condion.
When a condion lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO seng.
Sensor positions
threshold a programmable
% offset above the
presented condition
Threshold position
adjusted by
Manual Adjust
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
Condition
Presented
Figure 11. Dark SET (Light Operate shown)
Dark SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds aer adjustment, the GREEN display will ash 3 mes to conrm
• Slide Mode switch to RUN to complete operaon
16
See Troubleshoong on page 25 for more explanaon of the % Oset displayed aer the Light SET method
DF-G3 Long Range Expert
™
Dual Display Fiber Amplier
22 www.bannerengineering.com - Tel: 763.544.3164