• —Master sync line output for two-sensor cross-talk avoidance
•
—Slave sync line input for two-sensor cross-talk avoidance
To configure sensors for master-slave operation, see Sync Master/Slave on page 24
.
3.2.10 Display View
Use this menu to select the display view. The default is right-reading.
•
—Right-reading
• —Inverted
•
—Right-reading and the display enters sleep mode after 60 seconds
• —Inverted and the display enters sleep mode after 60 seconds
When the sensor is in sleep mode, the display wakes with the first button press.
3.2.11 Exit Setup Mode
Navigate to and press SELECT to exit Setup mode and return to Run mode.
3.2.12 Reset to Factory Defaults
Use this menu to restore the sensor to the factory default settings. See Factory Default Settings on page
13.
Select
to return to the sensor menu without restoring the defaults. Select to apply the factory defaults and
return to Run mode.
Factory Default Settings
Setting Factory Default
Delay Timers ( ) —No delay
Display View ( ) —Right-reading, no sleep mode
Gain and Sensitivity ( ) —High excess gain mode
Input Wire Function (
) —Ignore all remote input pulses
If the sensor was reset using the remote input, the sensor
remains in mode to allow use of the remote input.
LO/DO LO—Light Operate
Response Speed ( ) —10 ms
Shift the Zero Reference Location after a TEACH ( ) —0 = the end of barrel
TEACH Mode (
) —Two-point TEACH
Zero Reference Location ( ) —Measurement increases further from sensor
3.3 Manual Adjustments
Manually adjust the sensor switch point using the and buttons.
1. From Run mode, press either or one time. The current switch point value flashes slowly.
Q4X Stainless Steel Laser Sensor
www.bannerengineering.com - Tel: 763.544.3164 13