Condition TEACH Result Display
One invalid TEACH Point
Sets a window (two switch points) centered
around the following location:
Model Window Center
Point
100 mm threaded barrel models 80
300 mm threaded barrel models 250
110 mm flush mount models 90
310 mm flush mount models 260
The window size is:
Model Window Size
100 mm threaded barrel models ±12.5 mm
300 mm threaded barrel models ± 25 mm
110 mm flush mount models ±12.5 mm
310 mm flush mount models ± 25 mm
and the window center
point distance flash alternately on
the display.
3.6.4 One-Point Background Suppression
One-point background suppression sets a single switch point in front of the taught target distance. Objects beyond the
taught switch point are ignored.
The switch point is set in front of the taught target distance by the vertical minimum
object separation. See Figure 20 on page
28.
Press and Hold
> 2s
Press again
Switch
Point
Value A
2
1
3
Figure 17. One-Point Background Suppression
NOTE: The sensor must be set to = to use the following instructions. The BGS indicator is amber
to indicate Background Suppression mode.
NOTE: To program the sensor using remote input, remote input must be enabled ( = ).
1. Present the target.
Method Action Result
Push Button
Present the target. The sensor-to-target distance must be within the
sensor's range.
The target's measurement value
displays.
Remote Input
2. Start the TEACH mode.
Q4X Stainless Steel Laser Sensor
www.bannerengineering.com - Tel: 763.544.3164 21