Loading...
Method Action Result
Push Button Press TEACH to stop teaching the sensor.
The new switch point flashes rapidly
and the sensor returns to Run mode.
Remote Input Single-pulse the remote input.
T
Table 3: Expected TEACH Behavior for Dynamic Background Suppression
See Figure 20 on page 28
for the minimum object separation.
Condition TEACH Result Display
Two valid distances that are
greater than or equal to the
horizontal minimum object
separation
Sets a switch point between the two taught
distances.
The switch point distance flashes
on the display.
Two valid distances that are less
than the horizontal minimum
object separation
Sets a switch point in front of the furthest
taught distance by the horizontal minimum
object separation.
and the switch point
distance flash alternately on the
display.
One valid distance with one invalid
TEACH point
Sets a switch point between the one taught
distance and the maximum range.
and the switch point
distance flash alternately on the
display.
Two invalid TEACH points
Sets a switch point at the following location:
Model Switch Point
100 mm threaded barrel models 75
300 mm threaded barrel models 200
110 mm flush mount models 85
310 mm flush mount models 210
and the switch point
distance flash alternately on the
display.
3.6.3 One-Point Window (Foreground Suppression)
One-point window sets a window (two switch points) centered around the taught target distance. Loss of signal is treated
as a detection in One-Point Window mode. The size of the taught window is the vertical minimum object separation. See
Figure 20 on page 28
.
Manually adjust the window size from Run mode using
and .
Switch
Point
Value A
Switch
Point
Value -A
2
Press and Hold
> 2s
1
3
Press again
Figure 16. One-Point Window (Foreground Suppression)
NOTE: The sensor must be set to = to use the following instructions. The FGS indicator is amber
to indicate One-Point Window (Foreground Suppression) mode.