3 Sensor Programming
Program the sensor using the buttons on the sensor or the remote input (limited programming options).
In addition to programming the sensor, use the remote input to disable the buttons for security, preventing unauthorized
or accidental programming changes. See Locking and Unlocking the Sensor Buttons on page
15
for more information.
3.1 Light Operate/Dark Operate
The default output configuration is light operate. To switch between light operate and dark operate, use the following
instructions:
1. Press and hold LO/DO for longer than 2 seconds. The current selection displays.
2.
Press LO/DO again. The new selection flashes slowly.
3. Press SELECT to change the output configuration and return to Run mode.
NOTE: If neither SELECT
nor LO/DO are pressed after step 2, the new selection flashes slowly for a few
seconds, then flashes quickly and the sensor automatically changes the output configuration and returns to
Run mode.
3.2 Setup Mode
Access Setup mode and the sensor menu from Run mode by pressing and holding MODE for longer than 2 seconds. Use
and to navigate through the menu. Press SELECT to select a menu option and access the submenus. Use and
to navigate through the submenus. Press SELECT to select a submenu option and return to the top menu, or press
and hold SELECT
for longer than 2 seconds to select a submenu option and return immediately to Run mode.
To exit Setup mode and return to Run mode, navigate to
and press SELECT.